Error Thrown:
Solution:
1. Goto AOT - Tables - NUMBERSEQUENCETABLE filter by recid from errored recid.
2. Find the NumberSequence value from the table.
3. Go to ORGANIZATION ADMINISTRATION-->COMMON-->NUMBER SEQUENCE
4. Edit the record and increase the LARGEST value to maximum and save.